Filter Attributes - Alarm Attributes
The following attributes are available for use throughout CygNet Software.
| Attribute | Attribute Name | Description | User Values |
|---|---|---|---|
|
Alarm Condition |
alarmcondition |
This attribute is used for filtering on the alarm condition of the point; for example, Analog Low Warning, Digital Alarm, Analog High Out-of-Range, etc. |
Text |
|
Alarm Hidden |
alarmhidden |
This attribute is used for filtering on an alarm that is either hidden or unhidden. |
Yes or No |
|
Alarm Priority Highest |
highestpriority |
This attribute is used for filtering on the highest numeric priority for the alarm. |
0-99 |
|
Alarm Priority Highest Category |
highestprioritycat |
This attribute is used for filtering on the highest alarm priority category for the alarm, for example, LOW, CRITICAL, MEDIUM, and HIGH. |
Text |
|
Alarm Priority Highest Category Description |
highestprioritycatdesc |
This attribute is used for filtering on the description for the highest category of a point’s alarm, for example, Low Alarm Priority, High Alarm Priority. Check spelling and capitalization. |
Text |
|
Alarm Priority Highest Since Ack |
highestpriorityunack |
This attribute is used for filtering on the highest alarm priority for the alarm since it was acknowledged. |
0-99 |
|
Alarm Priority Highest Since Ack Cat. |
highestpriorityunackcat |
This attribute is used for filtering on the highest alarm priority category for the alarm since acknowledgment (for example, LOW, CRITICAL, MEDIUM, and HIGH). |
LOW, CRITICAL, MEDIUM, HIGH |
|
Alarm Priority Highest Since Ack Cat. Desc |
highestpriorityunackcatdesc |
This attribute is used for filtering on the highest alarm priority category description for the alarm since it was acknowledged, for example, High Alarm Priority, Critical Alarm Priority, etc. |
Text |
|
Alarm Suppression State |
suppression |
This attribute is used for filtering on an alarm that is in a suppression state. |
Yes or No |
|
Facility Tag (CAS) |
factagcas |
This attribute is used for filtering on the facility tag. |
Text |
|
Point State |
pointstate |
This attribute is used for filtering on the point state of the alarm (for example, Analog Low Warning, Digital Normal, Unreliable, String Normal, etc.) |
Text |
|
Reported Time |
reporttime |
This attribute is used for filtering on the time when the alarm was last processed. |
Numeric (Time) |
|
Set/Reset State |
setreset |
This attribute is used for filtering on the set or reset state of the alarm. |
Yes or No |